SPECIFICATIONS
| Model Name | P1-06600-HFUF |
| Series | SJ-P1 Series |
| Voltage Class | 380-480 V AC (3-Phase) |
| Applicable Motor Capacity (VLD / LD / ND) | – / 355 kW / 315 kW |
| Rated Output Current (VLD / LD / ND) | – / 660 A / 600 A |
| Overload Capacity (VLD / LD / ND) | LD: 120 percent 60 s, 150 percent 3 s / ND: 150 percent 60 s, 200 percent 3 s |
| Main Power Supply | 3-Phase 380-500 V AC, 50/60 Hz |
| Control Power Supply | 1-Phase 380-500 V AC |
| Allowed Voltage Range | 323-550 V AC |
| Frequency Fluctuation | +/- 5 percent |
| Required Power Supply Capacity (VLD / LD / ND) | – / 599 kVA / 544 kVA |
| Dimensions (W x H x D) | 22.83 x 47.24 x 17.72 in |
Manuals and Specifications
| Users Guide | Hitachi SJP1 Users Guide |
| Quick Start Guide | Hitachi SJP1 Quick Start Guide |
| Catalog | Hitachi SJP1 Catalog |
| Brochure | Hitachi SJP1 Brochure |
| Basic Guide | Hitachi SJP1 Basic Guide |
SERIES DESCRIPTION
The SJ-P1 400 V P1-06600-HFUF is one of the highest capacity models in the series, supporting very large 315 kW motors in demanding industrial applications where reliability, control accuracy, and energy efficiency are critical.
Features
- Very high power 400 V inverter for large industrial drives
- Strong overload performance at light and normal duty
- Advanced vector control for induction and PM motors
- Built in PID, logic, arithmetic, and timing functions
- Energy saving, sleep, and diagnostic functions with LCD operator
- Standard RS-485 Modbus RTU communication